Arrow Exit Devices
 |
Arrow Exit Devices
|
|
 |
Arrow
Vertical Rod Exit Device S1150
Chassis & Cover:
Non-ferrous alloy
End caps: Metal
Doors:
- 1-3/4" (44.45 mm) thick,
- 3-3/4" for single doors, wood or hollow metal
- 3-1/2" (88.90 mm) minimum stile for double doors
Handing: Reversible
Dogging:
Allen-type key standard, cylinder available.
Top/Bottom Bolts/Latchbolt:
Brass 1/2" (12.7 mm) throw top, 3/4" (19.05 mm)
bottom
Throughbolts: Order separately
Rail Assembly: Steel
Rail Size:
- F Rail furnished standard for doors
up to 36", can be cut down to accommodate 32" doors.
- E Rail for doors up to 32", can be
cut down to accommodate 24" doors.
- G Rails for doors up to 48", can be
cut to accommodate 36" doors.
Rods: 90"extension kits available
Finishes: AL, BRZ, Powder Coat, LBZ, (sprayed
finishes)
Certification & Compliance:
ANSI/BHMA A156.3, Grade 1
Underwriters Laboratories (UL and CUL) listed for
accidoors, Prefix F before part number.
Made in the USA. |
| |
| |
Arrow
Rim Exit Device S1800
Chassis:
Pressure formed non-ferrous alloy
Chassis and end covers:
Cold drawn brass, bronze or stainless steel
Door Thickness:
1-3/4" (44.45 mm) standard, available for thick doors
Handing: Handed. Specify LHRB or RHRB
Dogging: Allen type only.
Top/Bottom Bolts: N/A
Latchbolt:
Stainless steel, 5/8" (15.875 mm) throw
Crossbar arms:
Forged brass and stainless steel
Crossbar:
1" (25.40 mm) brass, bronze and stainless steel tubing,
.062" (1.5875 mm) thick
Crossbar projection:
4-1/2" (114.3 mm) neutral, 2-3/4" (69.85 mm) depressed
Opening Height: N/A
Fire Exit Hardware-up to:
- 4' x 7'2" single door
- 8' x 7'2" pairs of doors with
- S21 mullion
Finishes:
US3,US4,US10,US10B,US26,US26D
Certification & Compliance:
ANSI/BHMA A156.3, Grade 1
Underwriters Laboratories (UL and CUL) listed for
accidoors, Prefix F before part number.
Made in the USA. |
| |
| |
Arrow
Exit Device 500 Series
Certification& Compliance
ANSI/BHMA A156.3, Grade 1
Underwriters Laboratories (UL and CUL) Listed for
accident hazard (panic) standard.
Fire Exit hardware for hollow metal doors, UL and CUL
listed for 3 hour, A label
and lesser doors, Suffix -FR after part number.
Fire Exit hardware for wood doors, listed up to 1-1/2
hour, B label doors
All exit devices comply with life safety code NFPA 101
All fire rated devices comply with fire door and
window code NFPA80.
Chassis: Non-ferrous materials
Chassis Cover: Black Lexan
Door Type: Hollow metal or aluminum
Door Thickness: 1-3/4" (44.5mm)
thick doors standard. 500DK Kits available for use with
161 door prep
Stile: 4-1/2" (144.30mm) minimum
Mounting: Wood and Machine screws
furnished standard
Handing: Reversible
Dogging: Hex-type hold down not
available with fire rated devices
Latchbolt: Stainless Steel
Rail Assembly: Powder Coated Steel
Fire Exit Hardware-up to: 4' x 8'
single door, 8' x 8' pairs of doors
Trim: Lever and Pull trims available
Finishes: Exit devices & Pulls: AL &
DBZ, Lever Trim 10B &26D
Strike: S38 Strike
Door Width: 530 Device is for 36"
door can be cut for a minimum 30" door width. 540 Device
is for 48" door can becut for a minimum 37" door width. |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
|